Fire Art & Guidelines
Click on each of these links to read the guidelines…
Guidelines for Fire in your Theme Camp
Guidelines for Flame Effects on Mutant Vehicles
…and then fill out the form:
2023 Transformus Flame Effects Application
Pre-Inspection Questions:
Before asking FAST for an inspection on-site please ask yourself the following questions to help ensure that all your equipment meets our technical requirements (full specifications available in Guidelines for Flame Effects)
Do you have:
- A 1/4 turn valve at each tank, before any hose and easily accessible in case of an emergency?
- Regulators designed for use with LPG?
- Valves marked with their pressure rating and LPG compatibility? (Documentation to confirm this is also sufficient)
- Hoses designed and marked for LPG with a minimum working pressure of 350 PSI and crimped fittings? (No hose clamps are allowed)
- Flare fittings used on all copper tubing? (No compressing fittings or solder allowed)
- Are accumulators made from unaltered DOT cylinders or ASME tanks?
For regulated pressures less than or equal to 125 PSI, use the following hardware:
- Minimum schedule 40 pipe & fittings
- Minimum 125 PSI valves
For regulated pressures greater than 125 PSI, use the following hardware:
- Minimum schedule 80 pipe & fittings
- Minimum 250 PSI valves